Skip to content
LAB 0221
HPA electronics · Cologne

Electronics for HPA airsoft replicas.

Lab 0221 is a one-person electronics lab in Cologne (0221 is the city’s area code). It builds a fire control unit you set up from your phone, the trigger boards that go with it, and a handheld chronograph. All three are in development. Nothing is for sale yet.

F1H rev D circuit board, top side
F1H · REV D · TOP SIDE

The products

3 products · all in development
F1H rev D circuit board, top view

F1H

● PROTOTYPING

Fire control unit

The F1H usually sits in the grip and drives the solenoids. You set poppet dwell, nozzle dwell and the ROF limit from your phone over Bluetooth, and you can check the battery there too. It is semi-auto only, so you get one shot per trigger pull. The dwell and ROF limits are enforced in the firmware, and the app cannot exceed them. It won’t arm below 3.4 V per cell. Updates come from the phone.

UNDER THE HOOD
Chip
nRF52840
Radio
Bluetooth LE, encrypted bonded pairing
Poppet dwell
1 to 20 ms
Nozzle dwell
5 to 60 ms
ROF limit
1 to 30 per second, or off
Low battery
No arming below 3.4 V per cell
Board
rev D (V0.0.5)
Firmware
0.1.0
C1 chronograph logic board, top view

C1

○ BOARDS DESIGNED

Handheld chronograph

The C1 is a chrono you hold in your hand and shoot through. It shows fps and joules for each shot, plus the average and spread for a series. Set your field’s joule limit and it flags every shot over it. Readings it can’t trust (reversed, incomplete or double) are thrown out. It tests its light gates every time it starts, and the start screen shows the firmware version.

UNDER THE HOOD
Sensing
Two light gates, 60 mm apart
Interface
OLED, 3 buttons
Radio
Bluetooth LE (no phone app for the C1 yet)
Boards
4
Revision
rev A
T1-L trigger board, top view

T1

● PROTOTYPING

Trigger boards for the F1H

The T1 sits at the trigger. It tells the F1H when you pull the trigger and whether the safety is on. A loose or broken safety cable reads as SAFE, and a hardware interlock blocks firing on safe. There are three versions: the T1-L uses a Hall sensor, the T1-M and T1-MS use a microswitch.

UNDER THE HOOD
Sensing
Hall sensor (T1-L) or microswitch (T1-M, T1-MS)
Safety line
Normally closed
Interlock
Hardware
Link
Wired, no radio
Board
rev A (V0.0.1)
Simulators

Try the F1H and the C1 in your browser.

Both simulators run in a browser tab. Change settings, fire, flip the safety and watch what the device does.

Under the hood: the same firmware core as the boards, compiled to WebAssembly.

Log

  1. Lab 0221 has a name. Every board now carries LAB 0221 on the back.

  2. C1 rev A: all four boards routed and ready for fab.

  3. F1H rev D: trigger interface for the T1 boards, with a hardware interlock.

Lab 0221 · Cologne No cookies, no tracking.